Sigen Energy Gateway Single Phase (SP) Datasheet 12Aug2025
Description
Sigen Energy Gateway for Australia
Sigen Gateway | Home SP AU | Units |
Grid Connection | ||
Grid connection type | Single phase | |
Nominal AC input / output voltage | 220 / 230 / 240 | V |
Nominal AC input / output current | 54.6 | A |
Nominal current of circuit breaker (The circuit breaker can be adjusted according to actual requirements and cable specifications) | 63 | A |
Nominal AC input / output power | 12 | kW |
Nominal AC frequency | 50 / 60 | Hz |
Disruption time of backup switch (This refers to the load-side disruption time, to achieve this functionality Sigen Energy Gateway needs to be used together with Sigen Energy Controller and Sigen Battery. Test conditions: In the open-circuit state of the power grid, the nominal power of the Sigen Energy Controller is higher than the total power of the backup loads) | 0 | ms |
AC Output to Backup Port | ||
Nominal AC output voltage | 220 / 230 / 240 | V |
Nominal AC output current | 54.6 | A |
Nominal current of circuit breaker (The circuit breaker can be adjusted according to actual requirements and cable specifications) | 63 | A |
Nominal AC output power | 12 | kW |
Nominal AC frequency | 50 / 60 | Hz |
Overvoltage category | III | |
AC Output to Non-Backup Port | ||
Nominal AC output voltage | 220 / 230 / 240 | V |
Nominal AC output current | 54.6 | A |
Nominal AC output power | 12 | kW |
Nominal AC frequency | 50 / 60 | Hz |
Inverter Connection | ||
Nominal AC voltage | 220 / 230 / 240 | V |
Nominal AC input current | 54.6 (INV1), 32 (INV2) (For Sigenergy single phase inverter products, 8.0-12.0 kW inverters should be connected to the INV1 port, 3.0-6.0 kW inverters should be connected to the INV2 port. The sum of the parallel power of the Sigenergy inverters cannot exceed 12 kW.) | A |
Nominal current of circuit breaker | 63 (INV1), 40 (INV2) | A |
Smart Port Connection | ||
Generator output voltage | 220 / 230 / 240 | V |
Nominal input / output current | 54.6 | A |
Nominal current of circuit breaker (The circuit breaker can be adjusted according to actual requirements and cable specifications) | 63 | A |
Nominal AC input / output power | 12 | kW |
Generator 2-wire start | Supported | |
General Data | ||
Dimensions (W / H / D) | 450 / 570 / 197 (without decorative cover) | mm |
Weight | 22.5 (without decorative cover) | kg |
Storage temperature range | -40 ~ 70 | °C |
Operating temperature range | -30 ~ 55 | °C |
Relative humidity range | 0% ~ 100% | |
Max. operation altitude | 4000 | m |
Cooling | Natural convection | |
Ingress protection rating | IP54 | |
Communication | Fast Ethernet , RS485, dry contact | |
Installation method | Wall mounted, rear wiring supported |