Product Features - Daikin Perfera - FVXM-R
✅ Seasonal efficiency values up to A+++ in cooling and heating
✅ Heat boost quickly heats up your home when starting up your air conditioner. Set temperature is reached 14% faster than a regular air conditioner (pair only)
✅ Using electrons to trigger chemical reactions with air borne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air
✅ Silver allergen removal and air purifying filter captures allergens such as pollen to ensure a steady supply of clean air
✅ Daikin Residential controller: control your indoor from any location with an app, via your local network or internet.
✅ Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
✅ Quiet operation: down to 19dBA sound pressure level
✅ 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces
✅ 2-area motion detection sensor: air flow is sent to a zone other than where the person is located at that moment; if no people are detected, the unit will automatically switch over to the energy-efficient setting. (larger capacity area)
Benefits - Daikin Perfera - FVXM-R
✅ Daikin Residential Controller: Control your indoor climate from any location via smartphone or tablet.
✅ Floor warming: Optimises convection by distributing hot air from the bottom of the unit.
✅ Heat boost: Quickly heats up your home when starting up your air conditioner. Set temperature is reached 20% faster than a regular air conditioner (pair only).
✅ Heat plus: Provides 30 minutes cosy heating by simulating radiant heat.
✅ Econo mode: Decreases power consumption so that other appliances that need large power consumption can be used. This function is also energy saving.
✅ Energy saving during standby mode: Current consumption is reduced by about 80% when operating on standby.
✅ Night set mode: Saves energy, by preventing overcooling or overheating during night time.
✅ Fan only: The unit can be used as fan, blowing air without heating or cooling.
✅ Comfort mode: Guarantees draught free operation by preventing that warm or cold air is directly blown on to the body.
✅ Powerful mode: Can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode.
✅ Auto cooling-heating changeover: Automatically selects heating or cooling mode to achieve the set temperature.
✅ Indoor unit silent operation: "Silent" button on the remote control lowers the operation sound of the indoor unit by 3dB(A).
✅ Outdoor unit silent operation: "Silent" button on the remote control lowers the operation sound of the outdoor unit by 3dB(A) to ensure a quiet environment for the neighbourhood.
✅ Night quiet mode: Reduces automatically the operation sound during nighttime of the outdoor unit by 3dB(A) by removing an outdoor unit jumper wire. (Multi outdoor units in cooling mode only).
✅ Vertical auto swing: Possibility to select automatic vertical moving of the air discharge flaps for efficient air and temperature distribution throughout the room.
✅ Auto fan speed: Automatically selects the necessary fan speed to reach or maintain the set temperature.
✅ Fan speed steps (5 steps): Allows to select up to the given number of fan speed.
✅ Dry programme: Allows humidity levels to be reduced without variations in room temperature.
✅ Flash Streamer: Using electrons to trigger chemical reactions with air borne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air.
✅ Titanium apatite deodorising filter: Decomposes bothersome odours of for example tobacco and pets.
✅ Air filter: Removes airborne dust particles to ensure a steady supply of clean air.
✅ Weekly timer: Can be set to start heating or cooling anytime on a daily or weekly basis.
✅ 24 hour timer: Can be set to start operation anytime during a 24 hour period
✅ Infrared remote control: Starts, stops and regulates the air conditioner from a distance.
✅ Wired remote control: Starts, stops and regulates the air conditioner.
✅ Centralised control: Starts, stops and regulates several air conditioners from one central point.
✅ Auto-restart: The unit restarts automatically at the original settings after power failure.
✅ Self diagnosis: Simplifies maintenance by indicating system faults or operating anomalies.
✅ Multi model application - Up to 5 indoor units can be connected to a single outdoor unit, even if they have different capacities. All indoor units can individually be operated within the same heating or cooling mode.
✅ Practically inaudible: Practically inaudible: the unit runs so quietly, you will almost forget it is there.
✅ Silver allergen removal and air purifying filter: Captures allergens such as pollen and dust mites. The filter suppresses pollen and mites for 99% or more.
✅ 2 area motion detection sensor: Air flow is sent to a zone other than where the person is located at that moment. If no people are detected, the unit will automatically switch over to the energy efficient setting.
Specifications Table for FTXM-R
FTXM20R2V1B | FTXM20R5V1B | FTXM25R5V1B | FTXM25R2V1B | FTXM35R2V1B | FTXM35R5V1B | FTXM42R2V1B | FTXM50R2V1B | FTXM60R2V1B | FTXM71R2V1B | FTXM42R5V1B (Archived) | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power input | Cooling | Nom. | kW | 0.029 | 0.029 | 0.025 | 0.025 | 0.030 | 0.030 | 0.034 | 0.030 | 0.032 | 0.054 | 0.034 |
Heating | Nom. | kW | 0.023 | 0.023 | 0.022 | 0.022 | 0.027 | 0.027 | 0.038 | 0.032 | 0.035 | 0.060 | 0.038 | |
Casing | Colour | White | White | White | White | White | White | White | White | White | White | White | ||
Dimensions | Unit | Height | mm | 295 | 295 | 295 | 295 | 295 | 295 | 295 | 299 | 299 | 299 | 295 |
Width | mm | 778 | 778 | 778 | 778 | 778 | 778 | 778 | 998 | 998 | 998 | 778 | ||
Depth | mm | 272 | 272 | 272 | 272 | 272 | 272 | 272 | 292 | 292 | 292 | 272 | ||
Weight | Unit | kg | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 10.0 | 14.5 | 14.5 | 14.5 | 10.0 | |
Sound power level | Cooling | dBA | 57 | 57 | 57 | 57 | 58 | 58 | 60 | 58.0 | 60.0 | 60.0 | 60 | |
Heating | dBA | 54 | 54 | 54 | 54 | 54 | 54 | 60 | 58.0 | 59.0 | 61.0 | 60 | ||
Sound pressure level | Cooling | High | dBA | 41 | 41 | 41 | 41 | 45 | 45 | 45 | 44.0 | 46.0 | 47.0 | 45 |
Medium | dBA | 33 | 33 | 33 | 33 | 33 | 33 | 39 | 40.0 | 42.0 | 43.0 | 39 | ||
Low | dBA | 25 | 25 | 25 | 25 | 29 | 29 | 30 | 36.0 | 37.0 | 38.0 | 30 | ||
Silent operation | dBA | 19 | 19 | 19 | 19 | 19 | 19 | 21 | 27.0 | 30.0 | 32.0 | 21 | ||
Heating | High | dBA | 39 | 39 | 39 | 39 | 39 | 39 | 45 | 43.0 | 45.0 | 46.0 | 45 | |
Medium | dBA | 34 | 34 | 34 | 34 | 35 | 35 | 39 | 39.0 | 41.0 | 42.0 | 39 | ||
Low | dBA | 26 | 26 | 27 | 27 | 28 | 28 | 29 | 34.0 | 36.0 | 37.0 | 29 | ||
Silent operation | dBA | 20 | 20 | 20 | 20 | 20 | 20 | 21 | 31.0 | 33.0 | 34.0 | 21 | ||
Piping connections | Liquid | OD | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
Gas | OD | mm | 9.50 | 9.50 | 9.50 | 9.50 | 9.50 | 9.50 | 9.50 | 12.7 | 12.7 | 15.9 | 9.50 | |
Drain | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | |||
Control systems | Infrared remote control | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ARC466A67 | ||
Wired remote control | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | BRC073A1 | |||
Standard Accessories | Installation manual | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Operation manual | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
Wireless remote control | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
AAA dry-cell batteries | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |||
Remote control holder | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
Mounting plate | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
Titanium apatite deodorizing filter | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 1 | |||
Indoor unit fixing screws | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |||
WLAN adapter kit | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |||
Power supply | Name | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | V1 | ||
Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | |||
Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||
Voltage | V | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | ||
Notes | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (1) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (1) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | |||
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | ||||
Standard Accessories | Silver particle filter | 1 | 1 | 1 |