Sigen Energy Gateway Three Phase (TP) Datasheet 12Aug2025
Description
Sigen Energy Gateway for Australia
| Sigen Gateway | Home TP AU | Units |
Grid Connection | ||
| Grid connection type | Three phase | |
| Nominal AC input / output voltage | 380 / 400 | V |
| Nominal AC input / output current | 45.6 | A |
Nominal current of circuit breaker (The circuit breaker can be adjusted according to actual requirements and cable specifications) | 63 | A |
| Nominal AC input / output power | 30 | kW |
| Nominal AC frequency | 50 / 60 | Hz |
| Disruption time of backup switch (This refers to the load-side disruption time, to achieve this functionality Sigen Energy Gateway needs to be used together with Sigen Energy Controller and Sigen Battery. Test conditions: In the open-circuit state of the power grid, the nominal power of the Sigen Energy Controller is higher than the total power of the backup loads) | 0 | ms |
AC Output to Backup Port | ||
| Nominal AC output voltage | 380 / 400 | V |
| Nominal AC output current | 45.6 | A |
Nominal current of circuit breaker (The circuit breaker can be adjusted according to actual requirements and cable specifications) | 63 | A |
| Nominal AC output power | 30 | kW |
| Nominal AC frequency | 50 / 60 | Hz |
| Overvoltage category | III | |
AC Output to Non-Backup Port | ||
| Nominal AC output voltage | 380 / 400 | V |
| Nominal AC output current | 45.6 | A |
| Nominal AC output power | 30 | kW |
| Nominal AC frequency | 50 / 60 | Hz |
Inverter Connection | ||
| Nominal AC voltage | 380 / 400 | V |
| Nominal AC input current | 45.6 (INV1), 32 (INV2) (For Sigenergy three phase inverter products, 15.0-30.0 kW inverters should be connected to the INV1 port, 5.0-15.0 kW inverters should be connected to the INV2 port. The sum of the parallel power of the Sigenergy inverters cannot exceed 30 kW.) | A |
| Nominal current of circuit breaker | 63 (INV1), 40 (INV2) | A |
Smart Port Connection | ||
| Generator output voltage | 380 / 400 | V |
| Nominal input / output current | 45.6 | A |
Nominal current of circuit breaker (The circuit breaker can be adjusted according to actual requirements and cable specifications) | 63 | A |
| Nominal AC input / output power | 30 | kW |
| Generator 2-wire start | Supported | |
General Data | ||
| Dimensions (W / H / D) | 450 / 570 / 197 (without decorative cover) | mm |
| Weight | 25.5 (without decorative cover) | kg |
| Storage temperature range | -40 ~ 70 | °C |
| Operating temperature range | -30 ~ 55 | °C |
| Relative humidity range | 0% ~ 100% | |
| Max. operation altitude | 4000 | m |
| Cooling | Natural convection | |
| Ingress protection rating | IP54 | |
| Communication | Fast Ethernet , RS485, dry contact | |
| Installation method | Wall mounted, rear wiring supported | |