Skip to main content

AVG NRI-PRV-15C-I Specifications

Description

Non Return Isolation Pressure Reduction Valve Combination, NRI-PRV

NON RETURN ISOLATION PRESSURE REDUCTION VALVE COMBINATION

A non return isolation pressure reduction valve (NRI-PRV) can be a valuable addition to many piping systems. If the incoming water pressure is too high, this can put unnecessary strain on water heaters, pipe work, plumbing joints, taps and tap washers. It can increase the risk of burst hoses on washing machines, water leaks and possibly magnify any existing water hammer problems. The valves are factory set at 500 kPa. The down stream pressure is adjustable from 250 to 650 kPa by turning the screw on top.

Clockwise to increase pressure and anticlockwise to reduce pressure. For pressure monitoring, there are three gauge ports standard on the body of the valve so that a gauge can be fitted to monitor the upstream and downstream pressure. The tagging eye has been cast into the NRI-PRV body to allow the valve to be identified and tagged for mechanical service.

Pure Electric NRI PRV Pressure Adjustment
NRI PRV Pressure Reduction Photo Example
Clockwise to increase pressure
Anticlockwise to reduce pressure

NRI-PRV Features

  • Adjustable Range 250 650 kPa
  • Compact design
  • Factory set at 500 kPa
  • DZR brass valve body
  • Internal strainer
  • High Flow rate
  • Non Return Isolating Valve incorporated
  • Valve insulation included

NRI-PRV-15C & NRI-PRV-20C


Flow Rate as per Appendix K @ 700 kPa dynamic

NRI-PRV-15C        set pressure 500 kPa          Flow Rate 55 L/Min set pressure 250 kPa    Flow Rate 22 L/Min

NRI-PRV-20C        set pressure 500 kPa          Flow Rate 120 L/Min set pressure 250 kPa Flow Rate 30 L/Min

MATERIAL SPECIFICATIONS

Body:                        DR Brass Control Spindle: DR Brass Components:    DR Brass

Seals:                       EDPM 70

Strainer:                   Stainless Steel

Seat:                         Stainless Steel 316

Spring:                     Stainless Steel

INSTALLATION

  • Flush out your lines to remove any debris or dirt particles that may cause the valve to malfunction.
  • The pressure reduction valve may be installed horizontally or vertically.
  • It is recommended that isolation valves be fitted either side of the pressure reduction valve to assist future maintenance operations.
  • The NRI-PRV15 and NRI-PRV20 are protected by an internal stainless steel filter. If the valve is being installed in an environment where fine dirt particles are present it is recommended that a line strainer be fitted upstream of the valve.
  • Ensure that the valve is installed in an accessible position for future maintenance operations.
  • Install the valve with the arrow on the valve body pointing in the direction of flow.
  • For best operation the inlet pressure should be at least 100 kPa higher than the outlet pressure.
  • Suitable for installation below ground in a suitable approved box.
  • If the installation is at risk of water hammer, fit a water hammer arrestor. Do not install PRV’s below ground unless the valve is fitted inside a protective box as to prevent damage and corrosion by chemicals in the soil.
  • If the pressure setting is important for the protection of equipment fit a pressure relief valve downstream of the valve.
     

loading
1300 86 78 73
Reviews
Products Review Pure-Electric

Product Review Rating

5.0
Based on 80 reviews
Google Review Pure-Electric

Google Review Rating

4.9
Based on 84 reviews
Trustpilot Review Pure-Electric

Trustpilot Rating

4.9
Based on 105 reviews
Wordofmouth Review Pure-Electric

Word of Mouth Rating

5.0
Based on 16 reviews
Facebook Review Pure-Electric

Facebook Rating

5.0
Based on 9 reviews