Description

Maintenance and Storage

 

Cleaning 

It is recommended that the battery system be cleaned periodically. If the enclosure is dirty, please use a soft, dry brush or a dust collector to remove the dust. Liquids such as solvents, abrasives, or corrosive liquids should not be used to clean the enclosure. 

Maintenance 

The battery module should be stored in an environment with a temperature range between -10°C~+50°C, and charged regularly according to the table below with no more than 0.5 C (C-rate is a measure of the rate at which a battery is charged and discharged relative to its maximum capacity) to the SOC of 30% after a long time of storage.

Storage environment temperatureRelative humidity of the storage environmentStorage timeSOC
Below -10℃/Not allowed/
-10~25℃5%~70%≤ 12 months25%≤SOC≤60%
25~35℃5%~70%≤ 6 months25%≤SOC≤60%
35~50℃5%~70%≤ 3 months25%≤SOC≤60%
Above 50℃/Not allowed/

NOTICE

Damage to the system due to under voltages

  • Charge the over-discharged system within seven days when the temperature is above 25 °C. 

  • Charge the over-discharged system within fifteen days when the temperature is below 25 °C.