Skip to main content

Trina Vertex S+ 450W

Trina Vertex S+ 450W

Available
In Stock

QUICK REVIEW

The Vertex S+ is a high-performance solar panel featuring dual-glass and N-type i-TOPCon cell technology, delivering enhanced durability, fire resistance, and recyclability. Ideal for both residential and commercial projects, this next-generation panel ensures long-term reliability with a 30-year power warranty and a 25-year product warranty.

Model: TSM-450NEG9R.28

Key Specifications:

  • Nominal Power: 450W

  • Panel Efficiency: 22.5%

  • Solar Cells: N-type i-TOPCon Monofacial Dual Glass

  • Power Warranty: 30 years

  • Product Warranty: 25 years

Electrical Parameters:

  • Open Circuit Voltage: 52.6V

  • Short Circuit Current: 10.71A

Mechanical Parameters:

  • Dimensions: 1762 x 1134 x 30mm

  • Weight: 21.0kg

Durability and Performance

The dual-glass design of the Vertex S+ enhances durability by providing increased resistance to micro-cracks and environmental stress. Paired with advanced N-Type i-TOPCon cell technology, it offers superior fire resistance, recyclability, and long-lasting performance, making it ideal for residential and commercial installations.

Sleek, Modern Design

With no front-grid lines, the Vertex S+ combines sleek aesthetics with practical functionality, enhancing the visual appeal of any rooftop installation.

Effortless Installation

The Vertex S+ is compact and easy to install, making it a perfect solution for residential rooftops and commercial projects alike.

High Efficiency with Low Degradation

Delivering high power output with minimal degradation, the Vertex S+ ensures consistent energy production over time, maintaining efficiency and reliability.

Comprehensive Warranty

Thanks to its dual-glass construction and N-Type i-TOPCon technology, the Vertex S+ comes with an industry-leading 30-year power warranty and a 25-year product warranty, offering long-term peace of mind.

Trina Solar’s Vertex Monofacial Dual Glass Performance Warranty
Trina Solar’s Vertex Monofacial Dual Glass Performance Warranty

Testimonials

What they are saying about us

you don't know how good a company is until you need a warranty claim actioning. I feel extremely lucky, I went with gut feeling and best price and still won. the horror stories I've heard since about...
J

Jon K.

Very knowledgeable team, great communication. Highly recommend them for managing a solar system install. We will definitely utilize their services for future additions and upgrades to our system. The ...
T

Tom R

I purchased a US7 reverse cycle air conditioner and Sanden heat pump hot water system from from Pure Electric. I'm very happy with the install and Matthew and Paul were very responsive to any question...
A

Alex Thompson

The team at Pure Electric are knowledgeable and friendly. Pricing seems very fair and they only stock the best quality gear. They have a focus on saving energy and users money which in turn helps the ...
P

phillo

F.A.Q

Frequently Asked Questions

  • If your house is single phase power, the amount of rooftop solar PV that you can install will depend  on your electricity network provider, as each electricity network provider has different rules.

    In almost all instances, you can install more inverter capacity than what the electricity network provider says, so long as you grid export limit your solar PV system.  Note:  Not all inverters have grid export limit capability. 

    Below is a table showing the allowed capacity (inverter capacity and your grid export limit), for each of the electricity network providers for single phase households:

    SA Power Networks (SA) max 10kW inverter capacity, 5kW export limit
    Powercor (VIC) no inverter limit, 5kW export limit
    CitiPower (VIC) no inverter limit, 5kW export limit
    Ausnet Services (VIC) max 10kW inverter capacity, 5kW export limit
    United Energy (VIC) max 10kW inverter capacity, 10kW export limit
    Jemena (VIC)  max 10kW inverter capacity, 10kW export limit
    Energex (QLD) max 10kW inverter capacity, 5kW export limit
    Ausgrid (NSW) max 10kW inverter capacity, 10kW export limit
    EVO Energy (ACT) max 10kW inverter capacity, 5kW export limit
  • There are many benefits in installing a solar PV system including:

    • Reduce or eliminate your power bill - you can regain control of your electricity costs. 
       
    • A revenue generating asset - you make back many times the initial cost of the system over the lifetime of your solar PV system.
       
    • Add value to your home - a solar system adds value to your home increasing the resale value. 
       
    • Reduce your carbon footprint - a solar system generates no greenhouse gases while in operation giving you zero carbon power and lowing your overall carbon footprint. 
  • You want as large a rooftop solar PV system as you can fit on your roof to reduce the amount of time you need to rely on your backup generator  that may be required for periods during winter periods or times of low solar radiation (i.e. multiple cloudy days).

    We generally recommend a minimum 10kW solar PV system, but the final size will depend on your anticipated load/demand. We can help you work this out by using our load profile sheet as part of our comprehensive quoting process.

Compact Size, More Power

  • Delivers up to 455W with a module efficiency of 22.8%, powered by high-density interconnect technology.
  • Multi-busbar design enhances light trapping, reduces series resistance, improves current collection, and increases overall reliability.
  • Higher power output and efficiency reduce installation costs.
  • Performs efficiently in warm climates thanks to a low temperature coefficient and operating temperature.

Dual-Glass Design for Security and Sustainability

  • Enhanced dual-glass construction reduces susceptibility to micro-cracks and scratches during installation.
  • Fire Class C rating for added safety.

Ultra-Low Degradation, Extended Warranty, Higher Output

  • 1% first-year degradation and just 0.4% annually thereafter.
  • Backed by a 25-year product warranty and a 30-year power warranty.

Versatile Solution for Residential and C&I Rooftops

  • Easy to integrate, compatible with most mainstream inverters and mounting systems.
  • Lightweight and compact for easy handling and installation.
  • Ideal for low-load capacity rooftops, offering mechanical performance of up to 5400 Pa for positive loads and 4000 Pa for negative loads.

MECHANICAL DATA

Solar CellsN-type Monocrystalline
No. of cells144 cells
Module Dimensions1762×1134×30 mm
Weight21.0kg
Front Glass1.6 mm, High Transmission, AR Coated Heat Strengthened Glass
Encapsulant materialPOE/EVA
Back Glass1.6mm, Heat Strengthened Glass
Frame30mm Anodized Aluminium Alloy, Black
J-BoxIP 68 rated
Cables

Photovoltaic Technology Cable 4.0mm2 (0.006 inches2),

Length: 1100mm/1100mm(43.3/43.3 inches)

ConnectorStabuli MC4 EVO2
DIMENSIONS OF TRINA VERTEX 450 PV MODULE(mm)

 

 

ELECTRICAL DATA (STC)

STC: Irrdiance 1000W/m2, Cell Temperature 25ºC, Air Mass AM1.5. *Measuring tolerance: ±3%.

Peak Power Watts-PMAX (Wp)*450
Binning Tolerance-PMAX (W)0 ~ +5
Maximum Power Voltage-VMPP (V)44.6
Maximum Power Current-IMPP (A)10.09
Open Circuit Voltage-VOC (V)52.9
Short Circuit Current-ISC (A)10.74
Module Efficiency η m (%)22.5

 

ELECTRICAL DATA (NOCT)

NOCT: Irradiance at 800W/m2, Ambient Temperature 20°C, Wind Speed 1m/s.

Maximum Power-PMAX (Wp)343
Maximum Power Voltage-VMPP (V)42.0
Maximum Power Current-IMPP (A)8.19
Open Circuit Voltage-VOC (V)50.2
Short Circuit Current-ISC (A)8.66

 

TEMPERATURE RATINGS

NOCT(Nominal Operating Cell Temperature)43°C (±2°C)
Temperature Coecient of PMAX-0.29%/°C
Temperature Coecient of VOC- 0.24%/°C
Temperature Coecient of ISC0.04%/°C

 

MAXIMUM RATINGS

Operational Temperature-40~+85ºC
Maximum System Voltage1500V DC (IEC)
Max Series Fuse Rating25A

 

CLEANING

Before cleaning, make sure to wear PPE, such as insulated protective gloves, protective glasses, hard hats, safety insulated shoes, etc.

Do not stand on the modules or trackers for cleaning work.

The amount of electricity generated by a solar module is proportional to the amount of light captured. A module with shaded cells generate less energy, and therefore, it is essential to keep PV modules clean. The dirt such as bird droppings, leaves, dust is usually need to be cleaned. 

When cleaning the modules, make sure that the temperature difference between the water and the module is in the range of -5℃ to 10℃. 

Use a dry or wet, soft and clean cloth, sponge, or soft bristled brush to wipe the photovoltaic module. Please make sure that the cleaning tools do not wear out glass, EPDM, silicon, aluminum alloys or steel.

If there is greasy dirt or other substances which are difficult to clean, conventional household glass cleaning agents can be used. Pay attention not to use alkaline and strong acidic solvents, including hydrofluoric acid, alkali, acetone. 

For modules that are installed horizontally (0° tilt angle), they should be cleaned more frequently, as they do not have "self-cleaning" function as those installed at 10° or larger tilt angles. 

The back surface of the monofacial module usually does not need to be cleaned. When cleaning the back of the bifacial module, avoid any sharp objects that may cause damage or penetrate the base material. The other cleaning requirements are the same as the front-side.

NOTES:

Take care to prevent foreign objects such as lawn mowers and rolled up stones from hitting the surface of modules that would cause the damage of glass or modules. 

Cleaning activities create risk of damaging the modules and array components, as well as increasing the potential electric shock hazard. 

Do not clean the modules during the hottest time of the day to avoid thermal stress on the modules. 

Cracked or broken modules represent an electric shock hazard due to leakage currents, and the risk of shock is increased when modules are wet. Before cleaning, thoroughly inspect modules for cracks, damage, and loose connections. 

During the daylight, the voltage and current present in the array are sufficient to cause a fatal electric shock. 

Please make sure that the array has been disconnected from other active components before starting the cleaning. 

Wear suitable protective clothing (clothes, insulating gloves, etc.) when cleaning the modules. 

Do not immerse the module, partially or totally, in water or any other cleaning solutions. 

Do not use such as lubricants and organic solvents to clean the connectors. 

Do not clean modules under the weather conditions of wind more than 4 class (in Beaufort scale), heavy rain or heavy snow. 

When cleaning the modules, it is forbidden to step on the modules, forbidden the injection of water to the backside of the modules or cables. Please ensure that the connectors are clean and dry to prevent electric shock and fire hazards. 

Do not use steam cleaner. 

For detailed requirements regarding cleaning, please refer to White Paper for PV Modules Operation and Maintenance, available from https://www.trinasolar.com/en-glb/resources/downloads.

Trina Vertex S+ 450 Datasheet

Trina Vertex S+ 450 Datasheet
More Details

Trina Vertex User Manual

Trina Vertex User Manual
More Details

Trina Vertex S+ Warranty

Trina Vertex S+ Warranty
More Details

loading
1300 86 78 73
Reviews
Products Review Pure-Electric

Product Review Rating

5.0
Based on 80 reviews
Google Review Pure-Electric

Google Review Rating

4.9
Based on 84 reviews
Trustpilot Review Pure-Electric

Trustpilot Rating

4.9
Based on 105 reviews
Wordofmouth Review Pure-Electric

Word of Mouth Rating

5.0
Based on 16 reviews
Facebook Review Pure-Electric

Facebook Rating

5.0
Based on 9 reviews